SWT’s single head adjustable metering pump is built with three detachable components; the motor, feed rate control, and the pump head. The output is determined by three factors; the rpm of the motor gears, the percentage setting on the feed rate control, and the size of the pump tube. The motor shaft rotates at a fixed rpm, which drives the feed rate control to intermittently engage the roller assembly within the pump head according to the setting on the external dial ring. The dial ring is labeled L to 10 and has a 20:1 turndown. |
|
|
Single Head Adjustable Output Pumps — 26 rpm — Low Pressure: 0 to 25 psi (1.7 bar)
(See Tube Output below for feed rate control settings) |
PART NUMBER |
TUBE SIZE |
OUTPUT |
CONNECTION
SIZE |
GPD @ 60 Hz |
LPD @ 50 Hz |
TS45M1 |
#1 |
0.2 to 3 |
0.6 to 9.1 |
1/4 inch |
TS45M2 |
#2 |
0.5 to 10 |
1.5 to 30.3 |
1/4 inch |
TS45M3 |
#3 |
1.1 to 22 |
3.3 to 66.6 |
1/4 inch |
TS45M4 |
#4 |
1.7 to 35 |
5.1 to 106.0 |
1/4 inch |
TS45M5 |
#5 |
2.5 to 50 |
7.6 to 151.4 |
1/4 inch |
TS45M1-3 |
#1 |
0.2 to 3 |
0.6 to 9.1 |
3/8 inch |
TS45M2-3 |
#2 |
0.5 to 10 |
1.5 to 30.3 |
3/8 inch |
TS45M3-3 |
#3 |
1.1 to 22 |
3.3 to 66.6 |
3/8 inch |
TS45M4-3 |
#4 |
1.7 to 35 |
5.1 to 106.0 |
3/8 inch |
TS45M5-3 |
#5 |
2.5 to 50 |
7.6 to 151.4 |
3/8 inch |
|
|
Single Head Adjustable Output Pumps — 26 rpm — High Pressure: 0 to 100 psi (6.9 bar)
(See Tube Output below for feed rate control settings) |
PART NUMBER |
TUBE SIZE |
OUTPUT |
CONNECTION
SIZE |
GPD @ 60 Hz |
LPD @ 50 Hz |
TS45MHP2 |
#1 |
0.2 to 3 |
0.6 to 9.1 |
1/4 inch |
TS45MHP10 |
#2 |
0.5 to 10 |
1.5 to 30.3 |
1/4 inch |
TS45MHP22 |
#7 |
1.1 to 22 |
3.3 to 66.6 |
1/4 inch |
TS45MHP2-3 |
#1 |
0.2 to 3 |
0.6 to 9.1 |
3/8 inch |
TS45MHP10-3 |
#2 |
0.5 to 10 |
1.5 to 30.3 |
3/8 inch |
TS45MHP22-3 |
#7 |
1.1 to 22 |
3.3 to 66.6 |
3/8 inch |
|
|
Single Head Adjustable Output Pumps — 44 rpm — Low Pressure: 0 to 25 psi (1.7 bar)
(See Tube Output below for feed rate control settings) |
PART NUMBER |
TUBE SIZE |
OUTPUT |
CONNECTION
SIZE |
GPD @ 60 Hz |
LPD @ 50 Hz |
TS85M1 |
#1 |
0.3 to 5 |
0.9 to 15.1 |
1/4 inch |
TS85M2 |
#2 |
0.8 to 17 |
2.4 to 51.5 |
1/4 inch |
TS85M3 |
#3 |
2.0 to 40 |
6.1 to 121.1 |
1/4 inch |
TS85M4 |
#4 |
3.0 to 60 |
9.1 to 181.7 |
1/4 inch |
TS85M5 |
#5 |
4.3 to 85 |
13.0 to 257.4 |
1/4 inch |
TS85M1-3 |
#1 |
0.3 to 5 |
0.9 to 15.1 |
3/8 inch |
TS85M2-3 |
#2 |
0.8 to 17 |
2.4 to 51.5 |
3/8 inch |
TS85M3-3 |
#3 |
2.0 to 40 |
6.1 to 121.1 |
3/8 inch |
TS85M4-3 |
#4 |
3.0 to 60 |
9.1 to 181.7 |
3/8 inch |
TS85M5-3 |
#5 |
4.3 to 85 |
13.0 to 257.4 |
3/8 inch |
|
|
Single Head Adjustable Output Pumps — 44 rpm — High Pressure: 0 to 100 psi (6.9 bar)
(See Tube Output below for feed rate control settings) |
PART NUMBER |
TUBE SIZE |
OUTPUT |
CONNECTION
SIZE |
GPD @ 60 Hz |
LPD @ 50 Hz |
TS85MHP5 |
#1 |
0.3 to 5 |
0.9 to 15.1 |
1/4 inch |
TS85MHP17 |
#2 |
0.8 to 17 |
2.4 to 51.5 |
1/4 inch |
TS85MHP40 |
#7 |
2.0 to 40 |
6.1 to 121.1 |
1/4 inch |
TS85MHP5-3 |
#1 |
0.3 to 5 |
0.9 to 15.1 |
3/8 inch |
TS85MHP17-3 |
#2 |
0.8 to 17 |
2.4 to 51.5 |
3/8 inch |
TS85MHP40-3 |
#7 |
2.0 to 40 |
6.1 to 121.1 |
3/8 inch |
|
|
NOTE: The above information is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment. Many variables can affect the output of the pump. The manufacturer recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs. |
|
|
Tube Output — 26 rpm Models — Gallons per Day @ 60 Hz |
MODEL |
TUBE
SIZE |
APPROXIMATE OUTPUT IN GALLONS PER DAY (24 HR) AT 60 Hz |
L |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
TS45 |
#1 |
0.2 |
0.3 |
0.6 |
0.9 |
1.2 |
1.5 |
1.8 |
2.1 |
2.4 |
2.7 |
3.0 |
#2 |
0.5 |
1.0 |
2.0 |
3.0 |
4.0 |
5.0 |
6.0 |
7.0 |
8.0 |
9.0 |
10.0 |
#3
#7 |
1.1 |
2.2 |
4.4 |
6.6 |
8.8 |
11.0 |
13.2 |
15.4 |
17.6 |
19.8 |
22.0 |
#4 |
1.7 |
3.5 |
7.0 |
10.5 |
14.0 |
17.5 |
21.0 |
24.5 |
28.0 |
31.5 |
35.0 |
#5 |
2.5 |
5.0 |
10.0 |
15.0 |
20.0 |
25.0 |
30.0 |
35.0 |
40.0 |
45.0 |
50.0 |
|
|
Tube Output — 26 rpm Models — Liters per Day @ 50 Hz |
MODEL |
TUBE
SIZE |
APPROXIMATE OUTPUT IN LITERS PER DAY (24 HR) AT 50 Hz |
L |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
TS45 |
#1 |
0.6 |
0.9` |
1.8 |
2.7 |
3.6 |
4.5 |
5.5 |
6.4 |
7.3 |
8.2 |
9.1 |
#2 |
1.5 |
3.0 |
6.1 |
9.1 |
12.1 |
15.1 |
18.2 |
21.2 |
24.2 |
27.3 |
30.3 |
#3
#7 |
3.3 |
6.6 |
13.3 |
20.0 |
26.6 |
33.3 |
40.0 |
46.6 |
53.3 |
60.0 |
66.6 |
#4 |
5.1 |
10.6 |
21.2 |
31.8 |
42.4 |
53.0 |
63.6 |
74.2 |
84.8 |
95.4 |
106.0 |
#5 |
7.6 |
15.1 |
30.3 |
45.4 |
60.6 |
75.7 |
90.8 |
106.0 |
121.1 |
136.3 |
151.4 |
|
|
Tube Output — 44 rpm Models — Gallons per Day @ 60 Hz |
MODEL |
TUBE
SIZE |
APPROXIMATE OUTPUT IN GALLONS PER DAY (24 HR) AT 60 Hz |
L |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
TS85 |
#1 |
0.3 |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
4.5 |
5.0 |
#2 |
0.8 |
1.7 |
3.4 |
5.1 |
6.8 |
8.5 |
10.2 |
11.9 |
13.6 |
15.3 |
17.0 |
#3
#7 |
2.0 |
4.0 |
8.0 |
12.0 |
16.0 |
20.0 |
24.0 |
28.0 |
32.0 |
36.0 |
40.0 |
#4 |
3.0 |
6.0 |
12.0 |
18.0 |
24.0 |
30.0 |
36.0 |
42.0 |
48.0 |
54.0 |
60.0 |
#5 |
4.3 |
8.5 |
17.0 |
25.5 |
34.0 |
42.5 |
51.0 |
59.5 |
68.0 |
76.5 |
85.0 |
|
|
Tube Output — 44 rpm Models — Liters per Day @ 50 Hz |
MODEL |
TUBE
SIZE |
APPROXIMATE OUTPUT IN LITERS PER DAY (24 HR) AT 50 Hz |
L |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
TS85 |
#1 |
0.9 |
1.5 |
3.0 |
4.5 |
6.1 |
7.6 |
9.1 |
10.6 |
12.1 |
13.6 |
15.1 |
#2 |
2.4 |
5.1 |
10.3 |
15.4 |
20.6 |
25.7 |
30.9 |
36.0 |
41.2 |
46.3 |
51.5 |
#3
#7 |
6.1 |
12.1 |
24.2 |
36.3 |
48.5 |
60.6 |
76.7 |
84.8 |
96.9 |
109.0 |
121.1 |
#4 |
9.1 |
18.2 |
36.3 |
54.5 |
76.7 |
90.8 |
109.0 |
127.2 |
145.3 |
163.5 |
181.7 |
#5 |
13.0 |
25.7 |
51.5 |
77.2 |
103.0 |
128.7 |
154.4 |
180.0 |
205.9 |
231.6 |
257.4 |
|
|
NOTE: The above information is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment. Many variables can affect the output of the pump. The manufacturer recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs. |
|