Resin Loaders
swtwater.com Resin Loading
SWT Resin Loaders provide a simple, fast, and clean way to load a tank. They're designed to work with Rigid brand or similar type vacuum hose. No gaskets are required for the use of these resin loaders. Two lengths of 2.5 inch O.D. vacuum hose and a vacuum are all that is required to operate the loaders. One hose is used to connect the loader to the vaccum, and the other hose is used to suck the media or resin through the loader and into the tank. Any media dust will be drawn into the vacuum, where it will be filtered out. Simple, Fast, Clean.
(Note: Vacuum, vacuum hose, tank, and media are NOT supplied with loaders.)
 
 
Resin Loader for 2.5 inch Tank Resin Loader for 4 inch Tank with 1-1/2 inch Riser Resin Loader for 4 inch Tank with up to 1-1/4 inch Riser Resin Loader for 4 inch Tank with 2 inch Riser
SM-MS800 SM-MS800-4 SM-MS800-4-2PP
Optional Resin Loader Adapter  
SM-MS800-ADPT SM-MS800-4-1
SM-MS800-4-NR
 
 
PART NUMBER DESCRIPTION
SM-MS800 Resin loader for 2.5" NPSM tank opening for 0.812" to 1.375" riser
SM-MS800-4 Resin loader for 4" #8 UN tank opening for 1-1/2" riser
SM-MS800-4-1 Resin loader for 4" #8 UN tank opening for up to 1-1/4" riser (riser socket 1.59" I.D. avg)
SM-MS800-4-2PP Resin loader for 4" #8 UN tank opening for 2" riser
SM-MS800-4-NR Resin loader for 4" #8 UN tank opening for no riser
SM-MS800-6-15 Resin loader for 6" #8 UN thread, or 6" SNA flange, or 6" ANSI flange tank opening for up to 1‑1/2" riser (riser socket 2.047" I.D. avg.)
SM-MS800-6-2 Resin loader for 6" #8 UN thread, or 6" SNA flange, or 6" ANSI flange tank opening for 2" riser
SM-MS800-6-NR Resin loader for 6" #8 UN thread, or 6" SNA flange, or 6" ANSI flange tank opening for no riser
SM-MS800-ADPT Optional adapter converts resin loader ports to 2" spigot PVC pipe size (2.375" O.D.)
 
 
Resin Loader Typical Assembly
 
(ABOVE) TYPICAL ASSEMBLY.
NOTE: Inlet hose should never be left unattended while vacuum is in operation.
Resin Loader Diagram
 
DIRECTIONS FOR USE:
1. Place one hose in the inlet side of the loader.
(See diagram above.)
2. Place one hose in the outlet side of the loader.
(See diagram above.)
3. Attach outlet hose to the vacuum side of the vacuum.
4. Hold end of inlet hose in your hand.
5. Place the loader on top of tank over riser.
6. Switch on vacuum and begin to load resin while moving the inlet hose in a back and forth motion allowing air to be drawn in with the resin.
 
 
IMPORTANT WARNINGS!
1.  Make sure the hose is not blocked at any time during loading!
2.  Do not force the end of the hose into a bag of media!
3.  Air needs to be drawn in with the media or your tank may implode!
4.  Do not allow unqualified individuals to operate or use the resin loader!
5.  Failure to correctly use the resin loader may result in catastrophic tank failure!
 
 
 
 
Safe Water Technologies, Inc.
996 Bluff City Boulevard
Elgin, IL 60120 USA
 
 
Telephone: +1.847.888.6900
Facsimile: +1.847.888.6924
E-mail: info@swtwater.com
http://www.swtwater.com

Last Updated: August 1, 2016