SWT’s dual head dual control adjustable metering pump is built with five detachable components; the motor, two feed rate controls, and two pump heads. The output is determined by three factors; the rpm of the motor gears, the percentage settings on the feed rate controls, and the size of the pump tubes in both heads. The motor shaft rotates at a fixed rpm, which drives the feed rate controls to intermittently engage the roller assembly within the pump heads according to the settings on the external dial rings. The dial rings are labeled L to 10 and have a 20:1 turndown. |
|
|
|
Determining Output for Dual Head Dual Control Models:
The outside head operates on a percentage of the inside head (close to motor). The output of the two heads is equal only on setting #10. Use the Tube Output Tables to select the desired output for the inside head. This will be the primary output. The outside head’s output will be a percentage of this amount.
Example Using TS100MDC5:
Inside head setting 4 = 20 gpd (60.6 lpd)
Outside head setting 3 = 30% of primary output
for 20 Gallons = 6 gpd
for 60.6 liters = 18.18 lpd
Both heads set on 10 = 50 gpd x 2 for a combined total of 100 gpd
151.40 lpd x 2 for a combined total of 302.80 lpd |
 |
Feed Rate Control Settings: Numbers on the dial are at 10% increments. Each gradation represents a 2.5% step. |
|
|
|
CAUTION: Do not put two chemicals that are dangerous when combined in a dual head dual control pump to avoid possible disastrous human error result. |
|
Dual Head Dual Control Pumps — 26 rpm — Low Pressure: 0 to 25 psi (1.7 bar)
(See Tube Output below for feed rate control settings) |
PART NUMBER |
TUBE SIZE |
OUTPUT |
CONNECTION
SIZE |
GPD @ 60 Hz |
LPD @ 50 Hz |
TS100MDC1 |
#1 |
0.2 to 3 |
0.6 to 9.1 |
1/4 inch |
TS100MDC2 |
#2 |
0.5 to 10 |
1.5 to 30.3 |
1/4 inch |
TS100MDC3 |
#3 |
1.1 to 22 |
3.3 to 66.6 |
1/4 inch |
TS100MDC4 |
#4 |
1.7 to 35 |
5.1 to 106.0 |
1/4 inch |
TS100MDC5 |
#5 |
2.5 to 50 |
7.6 to 151.4 |
1/4 inch |
TS100MDC1-3 |
#1 |
0.2 to 3 |
0.6 to 9.1 |
3/8 inch |
TS100MDC2-3 |
#2 |
0.5 to 10 |
1.5 to 30.3 |
3/8 inch |
TS100MDC3-3 |
#3 |
1.1 to 22 |
3.3 to 66.6 |
3/8 inch |
TS100MDC4-3 |
#4 |
1.7 to 35 |
5.1 to 106.0 |
3/8 inch |
TS100MDC5-3 |
#5 |
2.5 to 50 |
7.6 to 151.4 |
3/8 inch |
|
|
Dual Head Dual Control Pumps — 26 rpm — High Pressure: 0 to 100 psi (6.9 bar)
(See Tube Output below for feed rate control settings) |
PART NUMBER |
TUBE SIZE |
OUTPUT |
CONNECTION
SIZE |
GPD @ 60 Hz |
LPD @ 50 Hz |
TS100MDCHP5 |
#1 |
0.2 to 3 |
0.6 to 9.1 |
1/4 inch |
TS100MDCHP20 |
#2 |
0.5 to 10 |
1.5 to 30.3 |
1/4 inch |
TS100MDCHP5-3 |
#1 |
0.2 to 3 |
0.6 to 9.1 |
3/8 inch |
TS100MDCHP20-3 |
#2 |
0.5 to 10 |
1.5 to 30.3 |
3/8 inch |
|
|
Dual Head Dual Control Pumps — 44 rpm — Low Pressure: 0 to 25 psi (1.7 bar)
(See Tube Output below for feed rate control settings) |
PART NUMBER |
TUBE SIZE |
OUTPUT |
CONNECTION
SIZE |
GPD @ 60 Hz |
LPD @ 50 Hz |
TS170MDC1 |
#1 |
0.3 to 5 |
0.9 to 15.1 |
1/4 inch |
TS170MDC2 |
#2 |
0.8 to 17 |
2.4 to 51.5 |
1/4 inch |
TS170MDC3 |
#3 |
2.0 to 40 |
6.1 to 121.1 |
1/4 inch |
TS170MDC4 |
#4 |
3.0 to 60 |
9.1 to 181.7 |
1/4 inch |
TS170MDC5 |
#5 |
4.3 to 85 |
13.0 to 257.4 |
1/4 inch |
TS170MDC1-3 |
#1 |
0.3 to 5 |
0.9 to 15.1 |
3/8 inch |
TS170MDC2-3 |
#2 |
0.8 to 17 |
2.4 to 51.5 |
3/8 inch |
TS170MDC3-3 |
#3 |
2.0 to 40 |
6.1 to 121.1 |
3/8 inch |
TS170MDC4-3 |
#4 |
3.0 to 60 |
9.1 to 181.7 |
3/8 inch |
TS170MDC5-3 |
#5 |
4.3 to 85 |
13.0 to 257.4 |
3/8 inch |
|
|
Dual Head Dual Control Pumps — 44 rpm — High Pressure: 0 to 100 psi (6.9 bar)
(See Tube Output below for feed rate control settings) |
PART NUMBER |
TUBE SIZE |
OUTPUT |
CONNECTION
SIZE |
GPD @ 60 Hz |
LPD @ 50 Hz |
TS170MDCHP9 |
#1 |
0.3 to 5 |
0.9 to 15.1 |
1/4 inch |
TS170MDCHP34 |
#2 |
0.8 to 17 |
2.4 to 51.5 |
1/4 inch |
TS170MDCHP9-3 |
#1 |
0.3 to 5 |
0.9 to 15.1 |
3/8 inch |
TS170MDCHP34-3 |
#2 |
0.8 to 17 |
2.4 to 51.5 |
3/8 inch |
|
|
NOTE: The above information is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment. Many variables can affect the output of the pump. The manufacturer recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs. |
|
|
Tube Output — 26 rpm Models — Gallons per Day @ 60 Hz |
MODEL |
TUBE
SIZE |
APPROXIMATE OUTPUT IN GALLONS PER DAY (24 HR) AT 60 Hz |
L |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
TS100 |
#1 |
0.2 |
0.3 |
0.6 |
0.9 |
1.2 |
1.5 |
1.8 |
2.1 |
2.4 |
2.7 |
3.0 |
#2 |
0.5 |
1.0 |
2.0 |
3.0 |
4.0 |
5.0 |
6.0 |
7.0 |
8.0 |
9.0 |
10.0 |
#3 |
1.1 |
2.2 |
4.4 |
6.6 |
8.8 |
11.0 |
13.2 |
15.4 |
17.6 |
19.8 |
22.0 |
#4 |
1.7 |
3.5 |
7.0 |
10.5 |
14.0 |
17.5 |
21.0 |
24.5 |
28.0 |
31.5 |
35.0 |
#5 |
2.5 |
5.0 |
10.0 |
15.0 |
20.0 |
25.0 |
30.0 |
35.0 |
40.0 |
45.0 |
50.0 |
|
|
Tube Output — 26 rpm Models — Liters per Day @ 50 Hz |
MODEL |
TUBE
SIZE |
APPROXIMATE OUTPUT IN LITERS PER DAY (24 HR) AT 50 Hz |
L |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
TS100 |
#1 |
0.6 |
0.9` |
1.8 |
2.7 |
3.6 |
4.5 |
5.5 |
6.4 |
7.3 |
8.2 |
9.1 |
#2 |
1.5 |
3.0 |
6.1 |
9.1 |
12.1 |
15.1 |
18.2 |
21.2 |
24.2 |
27.3 |
30.3 |
#3 |
3.3 |
6.6 |
13.3 |
20.0 |
26.6 |
33.3 |
40.0 |
46.6 |
53.3 |
60.0 |
66.6 |
#4 |
5.1 |
10.6 |
21.2 |
31.8 |
42.4 |
53.0 |
63.6 |
74.2 |
84.8 |
95.4 |
106.0 |
#5 |
7.6 |
15.1 |
30.3 |
45.4 |
60.6 |
75.7 |
90.8 |
106.0 |
121.1 |
136.3 |
151.4 |
|
|
Tube Output — 44 rpm Models — Gallons per Day @ 60 Hz |
MODEL |
TUBE
SIZE |
APPROXIMATE OUTPUT IN GALLONS PER DAY (24 HR) AT 60 Hz |
L |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
TS170 |
#1 |
0.3 |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
4.5 |
5.0 |
#2 |
0.8 |
1.7 |
3.4 |
5.1 |
6.8 |
8.5 |
10.2 |
11.9 |
13.6 |
15.3 |
17.0 |
#3 |
2.0 |
4.0 |
8.0 |
12.0 |
16.0 |
20.0 |
24.0 |
28.0 |
32.0 |
36.0 |
40.0 |
#4 |
3.0 |
6.0 |
12.0 |
18.0 |
24.0 |
30.0 |
36.0 |
42.0 |
48.0 |
54.0 |
60.0 |
#5 |
4.3 |
8.5 |
17.0 |
25.5 |
34.0 |
42.5 |
51.0 |
59.5 |
68.0 |
76.5 |
85.0 |
|
|
Tube Output — 44 rpm Models — Liters per Day @ 50 Hz |
MODEL |
TUBE
SIZE |
APPROXIMATE OUTPUT IN LITERS PER DAY (24 HR) AT 50 Hz |
L |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
TS170 |
#1 |
0.9 |
1.5 |
3.0 |
4.5 |
6.1 |
7.6 |
9.1 |
10.6 |
12.1 |
13.6 |
15.1 |
#2 |
2.4 |
5.1 |
10.3 |
15.4 |
20.6 |
25.7 |
30.9 |
36.0 |
41.2 |
46.3 |
51.5 |
#3 |
6.1 |
12.1 |
24.2 |
36.3 |
48.5 |
60.6 |
76.7 |
84.8 |
96.9 |
109.0 |
121.1 |
#4 |
9.1 |
18.2 |
36.3 |
54.5 |
76.7 |
90.8 |
109.0 |
127.2 |
145.3 |
163.5 |
181.7 |
#5 |
13.0 |
25.7 |
51.5 |
77.2 |
103.0 |
128.7 |
154.4 |
180.0 |
205.9 |
231.6 |
257.4 |
|
|
NOTE: The above information is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment. Many variables can affect the output of the pump. The manufacturer recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs. |
|