Neutralizing Media
swtwater.com Neutralizer
Neutralizer — is a naturally occurring calcium carbonate media. One of the advantages of Neutralizer is its self-limiting property. When properly applied, it corrects pH only enough to reach a non-corrosive equilibrium. It does not overcorrect under normal conditions. Upon contact with Neutralizer, acidic waters slowly dissolve the calcium carbonate to raise the pH which reduces the potential leaching of copper, lead and other metals found in typical plumbing systems. Periodic backwashing will prevent packing, reclassify the bed and maintain high service rates. Depending on pH, water chemistry and service flow, the Neutralizer bed will have to be periodically replenished as the Neutralizer is depleted. Certified to NSF/ANSI/CAN Standard 60.
 
 
As the Neutralizer’s calcium carbonate neutralizes the water, it will increase hardness and a softener may become necessary after the neutralizing filter. Neutralizer can be effectively combined with Neutralizer Plus to combine the high flow neutralization properties of Neutralizer Plus, along with the slower reacting low flow properties of Neutralizer, increasing the ability to correct low pH.
 
PH10001 Pressure Drop Graph, corosex, A8011,
 
PRESSURE DROP — The graph above shows the expected pressure loss per foot of bed depth as a function of flow rate at various temperatures.
 
PH10001 Pressure Drop Graph, corosex, A8011,
 
BACKWASH — After each cycle the media bed should be backwashed at a rate that expands the bed 20 to 40 percent.
 
    Features:    
  Naturally occurring material  
  Low uniformity coefficient for maximum contact for controlled pH correction
 
  Slower reacting for controlled pH correction  
  Inexpensive
 
       
 
PART NUMBER
Neutralizer PH10003
 
PHYSICAL PROPERTIES
Color Near white
Bulk Density 90 lbs./cu. ft.
Mesh Size 16 x 40
Specific Gravity 2.7
Effective Size 0.4 mm
Uniformity Coefficient 1.5
Hardness 3.0 (Mohs scale)
Composition CaCO3: 95% min.
MgCO3: 3.0% max.
   
SUGGESTED OPERATING CONDITIONS
A gravel support bed is recommended
Water pH Range 5.0 - 7.0
Bed Depth 24 - 30 inches
Freeboard 50% minimum
Backwash Rate 8-12 gpm/sq. ft.
Backwash Bed Expansion 12% minimum
Service Flow Rate 3-6 gpm/sq. ft. but may be modified to adapt to local conditions
Max Usage 650 mg/L
Backwash Bed Expansion 20 to 40% of bed depth
 

 

This information has been gathered from standard materials and or test data that is believed to be accurate and reliable. Nothing herein shall be determined to be a warranty or representation expressed or implied with respect to the use of such information or the use of the goods described for any particular purpose alone or in combination with other goods or processes, or that their use does not conflict with existing patent rights. No license is granted to practice any patented invention. It is solely for your consideration, investigation and verification.

 
 
Ultraviolet Systems
Residential Systems
Accessories & Tools
Chemicals
  Drinking Water Systems
Commercial & Industrial
Media and Resins
Product Manuals
Reverse Osmosis Systems
Components
Filter Housings & Cartridges
Request For Quote
Safe Water Technologies, Inc.
996 Bluff City Boulevard
Elgin, IL 60120 USA
 
Telephone: +1.847.888.6900
Facsimile: +1.847.888.6924
E-mail: info@swtwater.com
https://www.swtwater.com

Last Updated: April 17, 2025