SPECIFICATIONS |
Part Number |
IT50001 |
US Standard Mesh Size
— Greater than 8
— Less than 30 |
8 x 30
5% maximum
3% maximum |
Backwash Expansion |
35% to 40% |
Backwash Rate |
12 gpm/sq.ft. @ 55°F |
Chlorine Reduction
@ 1ppm Influent
2 gpm flow rate per cu.ft.
4 gpm flow rate per cu.ft. |
1,000,000 gal
260,000 gal |
Iodine Number |
950 mg/g minimum |
Molasses Number |
200 mg/g minimum |
Abrasion Number |
90 ASTM minimum |
Methylene Blue |
150 mg/g minimum |
Benzene Number |
38 minimum |
CTC |
55 minimum |
Mean Particle Diameter |
1.5 to 1.7 mm |
Ash Content |
12% maximum |
Moisture |
3% maximum |
Bulk Density |
0.51 g/cc |
Net Weight |
27.5 lb / cu.ft. |
Packaging |
1 cu.ft. plastic lined, corrugated box |
|
|
TYPICAL PROPERTIES |
Total Surface Area
(N2 B.E.T. method) |
950 to 1,000 m²/g |
Pore Volume |
0.85 cc/g |
Backwash & Drained Density |
0.45 g/cc |
Uniform Coefficient |
2.0 |
Effective Size |
0.90 mm |
|
View SWT Filtration Media Guide |
|
|
ProActive™ is a trademark of Safe Water Technologies, Inc. |
|
|
|
Features: |
|
|
• |
High adsorption capacity and efficiency |
|
|
• |
Super durability that stands up well to backwash |
|
|
• |
Low fines, no floats, rinses fast |
|
|
• |
Certified to NSF/ANSI Standard 61 |
|
|
|
|
Warning
For safety and handling purposes, we recommend appropriate protective measures when entering a wet vessel
containing granular activated carbon, because wet activated carbon depletes oxygen from air and therefore,
dangerously low levels of oxygen may be encountered. In such a case, the oxygen level inside the vessel
shall be determined before entering and appropriate protective equipment should be worn when entering, or
leave the vessel open until the oxygen level in the vessel is normal. |
|
|
This information has been gathered from standard materials and or test data
that is believed to be accurate and reliable. Nothing herein shall be determined to be a warranty or
representation expressed or implied with respect to the use of such information or the use of the goods
described for any particular purpose alone or in combination with other goods or processes, or that
their use does not conflict with existing patent rights. No license is granted to practice any patented
invention. It is solely for your consideration, investigation and verification.
|
|