Packaging |
0.5 cu.ft. bags
48 bags/pallet |
0.5 cu.ft. bags
55 bags/pallet |
Service Flow Rate |
2 to 12 gpm/sq.ft. continuous |
2 to 5 gpm/sq.ft. continuous |
Clean Filter Pressure Drop
@ 5 gpm/sq.ft. |
0.8 psi per foot of bed depth |
0.8 psi per foot of bed depth |
Methods of Regeneration |
Intermittent or continuous feed
using Cl2 or O2 |
Intermittent or continuous feed
using Cl2 |
Certification |
NSF tested and certified to
NSF/ANSI/CAN Standard 61.
REACH pending. |
WQA tested and certified to
NSF/ANSI/CAN Standard 61.
REACH registered. |
Initial Startup |
Cl2 sterilization recommended
but not required |
Requires minimum 4 hours Cl2
regeneration |
Commercial Systems
Larger than 36 inch Tanks |
Air/water scour backwash |
Air/water scour backwash |