E Series
Controller |
NXT Series
Controller |
|
Max. Pressure: 125 psi (8.6 bar)
Max. Temperature: 140°F (60°C) |
|
|
|
|
|
Softeners—A100 Series Electromechanical Time Initiated Controller with Stager
DISCONTINUED: JUNE, 2012 — REPLACEMENT PARTS AVAILABLE |
Model Number |
Description |
Stager Port Size NPT |
Inlet |
Drain |
Control |
A148-00 |
Softener, 4 Cycle, Single Tank |
1/8" |
1/8" |
1/8" |
A151-07 |
Softener, 5 Cycle, Single Tank with Timed Brine |
1/8" |
1/8" |
1/8" |
A151-09 |
Softener, 5 Cycle, Single Tank with Timed Refill |
1/8" |
1/8" |
1/8" |
A151-06 |
Softener, 6 Cycle, Single Tank with Timed Brine and Refill |
1/8" |
1/8" |
1/8" |
A158-TA |
Softener, Twin Alternating with Service Lights |
1/4" |
1/4" |
1/8" |
|
A100 Series Part Number Matrix and Stager Program Guide PDF |
Please specify voltage requirement: 115VAC/60Hz or 230VAC/50-60Hz.
Other voltages may be available, contact your SWT representative for details. |
Please specify 6-Day or 7-Day clock timer. |
|
|
Softeners—E Series Electronic Demand/Metered Initiated Controller with Stager
|
Model Number |
Description |
Stager Port Size NPT |
Inlet |
Drain |
Control |
E948-00 |
Softener, 4 Cycle, Single Tank |
1/8" |
1/8" |
1/8" |
E948-12 |
Softener, 4 Cycle, Single Tank with Upflow Brine |
1/8" |
1/8" |
1/8" |
E948-03 |
Softener, 4 Cycle, Single Tank with Butterfly Cam |
1/8" |
1/8" |
1/8" |
E951-07 |
Softener, 5 Cycle, Single Tank with Timed Brine |
1/8" |
1/8" |
1/8" |
E951-09 |
Softener, 5 Cycle, Single Tank with Timed Refill |
1/8" |
1/8" |
1/8" |
E951-06 |
Softener, 6 Cycle, Single Tank with Timed Brine and Refill |
1/8" |
1/8" |
1/8" |
E951-12 |
Softener, 6 Cycle, Single Tank with Brine Recycle |
1/8" |
1/8" |
1/8" |
E948-TA |
Softener, Twin Alternating with Butterfly Cam |
1/8" |
1/8" |
1/8" |
E958-TA |
Softener, Twin Alternating with Service Lights |
1/4" |
1/4" |
1/8" |
E958-TB |
Softener, Twin Alternating with Timed Brine |
1/4" |
1/4" |
1/8" |
|
E Series Part Number Matrix and Stager Program Guide PDF |
Please specify voltage requirement: 115VAC/50-60Hz or 230VAC/50-60Hz. |
Optional Relay Output available on single units only (P/N: QA-1077737). |
PWA Circuit Board and Key Pad Assembly available (P/N: QA-1078458). |
|
|
Softeners—NXT Series Electronic Controller with Stager
|
Model Number |
Description |
Stager Port Size NPT |
Inlet |
Drain |
Control |
NX48-00 |
Softener, 4 Cycle, Single Tank |
1/8" |
1/8" |
1/8" |
NX51-06 |
Softener, 6 Cycle, Single Tank with Timed Brine and Refill |
1/8" |
1/8" |
1/8" |
|
NXT Series Part Number Matrix and Stager Program Guide PDF |
Please specify voltage requirement: 115VAC or 220VAC. |
Replacement PWA Circuit Board and Key Pad Kit available (P/N: QA-61784-01). |
Solenoid Kit available (P/N: QA-61783). |
CAT 5 Cable with Liquidtight Fittings available (P/N: QA-61764). |
Many custom programs are available. Please contact Technical Support for additional information. |
|
|
Filters—A100 Series Electromechanical Time Initiated Controller with Stager
DISCONTINUED: JUNE, 2012 — REPLACEMENT PARTS AVAILABLE |
Model Number |
Description |
Stager Port Size NPT |
Inlet |
Drain |
Control |
A148-01 |
Filter, 3 Cycle, Single Tank |
1/8" |
1/8" |
1/8" |
A151-11 |
Filter, 5 Cycle, Single Tank with Air Scour |
1/8" |
1/8" |
1/8" |
A151-10 |
Filter, 3 Cycle, 2 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
A148-83 |
Filter, 2 Cycle, 3 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
A158-03 |
Filter, 3 Cycle, 3 Tank Parallel with Sequential Backwash |
1/4" |
1/4" |
1/8" |
A148-84 |
Filter, 2 Cycle, 4 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
A158-04 |
Filter, 3 Cycle, 4 Tank Parallel with Sequential Backwash |
1/4" |
1/4" |
1/8" |
A148-85 |
Filter, 2 Cycle, 5 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
A151-86 |
Filter, 2 Cycle, 6 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
A151-87 |
Filter, 2 Cycle, 7 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
|
A100 Series Part Number Matrix and Stager Program Guide PDF |
Please specify voltage requirement: 115VAC/60Hz or 230VAC/50-60Hz.
Other voltages may be available, contact your SWT representative for details. |
Please specify 6-day or 7-day clock timer. |
|
|
Filters—E Series Electronic Demand/Metered Initiated Controller with Stager
|
Model Number |
Description |
Stager Port Size NPT |
Inlet |
Drain |
Control |
E948-04 |
Filter, 2 Cycle, Single Tank |
1/8" |
1/8" |
1/8" |
E948-01 |
Filter, 3 Cycle, Single Tank |
1/8" |
1/8" |
1/8" |
E948-12 |
Filter, 4 Cycle, Single Tank with Air Scour |
1/8" |
1/8" |
1/8" |
E951-11 |
Filter, 5 Cycle, Single Tank with Air Scour |
1/8" |
1/8" |
1/8" |
E958-01 |
Filter, 5 Cycle, Single Tank with Double Acting Valves |
1/4" |
1/4" |
1/8" |
E951-10 |
Filter, 3 Cycle, 2 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
E948-83 |
Filter, 2 Cycle, 3 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
E958-03 |
Filter, 3 Cycle, 3 Tank Parallel with Sequential Backwash |
1/4" |
1/4" |
1/8" |
E948-84 |
Filter, 2 Cycle, 4 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
E958-04 |
Filter, 3 Cycle, 4 Tank Parallel with Sequential Backwash |
1/4" |
1/4" |
1/8" |
E948-85 |
Filter, 2 Cycle, 5 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
E951-86 |
Filter, 2 Cycle, 6 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
E951-87 |
Filter, 2 Cycle, 7 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
|
E Series Part Number Matrix and Stager Program Guide PDF |
Please specify voltage requirement: 115VAC/50-60Hz or 230VAC/50-60Hz. |
Optional Relay Output available on single units only (P/N: QA-1077737). |
PWA Circuit Board and Key Pad Assembly available (P/N: QA-1078458). |
|
|
Filters—NXT Series Electronic Controller with Stager
|
Model Number |
Description |
Stager Port Size NPT |
Inlet |
Drain |
Control |
NX51-10 |
Filter, 3 Cycle, 2 Tank Parallel with Sequential Backwash |
1/8" |
1/8" |
1/8" |
|
NXT Series Part Number Matrix and Stager Program Guide PDF |
Please specify voltage requirement: 115VAC or 220VAC. |
Replacement PWA Circuit Board and Key Pad Kit available (P/N: QA-61784-01). |
Solenoid Kit available (P/N: QA-61783). |
CAT 5 Cable with Liquidtight Fittings available (P/N: QA-61764). |
Many custom programs are available. Please contact Technical Support for additional information. |
|
|
AQUAMATIC DIAPHRAGM VALVES |
|
|
|
|
|
K52 Series Valve
(Composite) |
K53 Series Valve
(Composite) |
K55 Series Valve
(Composite) |
V42 Series Valve
(Cast Iron) |
V46 Series Valve
(Stainless Steel) |
|
|
K52 Series Composite Valves |
Model |
Pipe Size |
Flow Coefficient |
Inches |
Millimeters |
Cv |
Kv |
K520 |
0.5 |
15 |
4.0 |
3.5 |
K521 |
1.0 |
25 |
15.0 |
13.0 |
K524 |
1.5 to 2.0 |
40 to 50 |
38.0 |
32.8 |
K526 |
2.5 to 3.0 |
65 to 80 |
100.0 |
86.5 |
|
View K52 Product Details |
K52 Part Number Matrix PDF |
Composite Valve Adapter Kits PDF |
Cv flow rate in gallons per minute of water at 60ºF, 1 psi pressure drop. |
Kv flow rate in cubic meters per hour of water at 15.5ºC, 1 bar pressure drop. |
Maximum working pressure is 125 psi (8.6 bar). |
Maximum temperature is 140°F (60°C). |
|
|
K53 Series Composite Valves |
Model |
Pipe Size |
Flow Coefficient |
Inches |
Millimeters |
Cv |
Kv |
K531 |
0.75 to 1.0 |
20 to 25 |
18.0 |
15.6 |
K534 |
1.5 |
40 |
46.0 |
39.8 |
K535 |
2.0 |
50 |
84.0 |
72.6 |
K537 |
3.0 |
80 |
200.0 |
173.0 |
|
View K53 Product Details |
K53 Part Number Matrix PDF |
Composite Valve Adapter Kits PDF |
Cv flow rate in gallons per minute of water at 60ºF, 1 psi pressure drop. |
Kv flow rate in cubic meters per hour of water at 15.5ºC, 1 bar pressure drop. |
Maximum working pressure is 125 psi (8.6 bar). |
Maximum temperature is 140°F (60°C). |
|
|
K55 Series Composite Valves |
Model |
Pipe Size |
Flow Coefficient |
Inches |
Millimeters |
Cv |
Kv |
K5520 |
0.5 |
15 |
4.0 |
3.5 |
K5521 |
1.0 |
25 |
15.0 |
13.0 |
K5524 |
1.5 to 2.0 |
40 to 50 |
38.0 to 41.0 |
32.8 to 35.5 |
|
View K55 Product Details |
K55 Part Number Matrix PDF |
Composite Valve Adapter Kits PDF |
Cv flow rate in gallons per minute of water at 60ºF, 1 psi pressure drop. |
Kv flow rate in cubic meters per hour of water at 15.5ºC, 1 bar pressure drop. |
Maximum working pressure is 125 psi (8.6 bar). |
Maximum temperature is 140°F (60°C). |
|
|
V42 Series Cast Iron Valves |
Model |
Pipe Size |
Flow Coefficient |
Inches |
Millimeters |
Cv |
Kv |
V42B |
0.75 |
20 |
11.4 |
9.8 |
V42C |
1.0 |
25 |
12.8 |
11.1 |
V42D |
1.25 |
32 |
26.5 |
22.9 |
V42E |
1.5 |
40 |
32.5 |
28.1 |
V42F |
2.0 |
50 |
56.0 |
48.4 |
V42G |
2.0 |
50 |
68.0 |
58.8 |
V42H |
2.5 |
65 |
84.0 |
72.7 |
V42J |
3.0 |
80 |
134.0 |
116.0 |
V42K |
4.0 |
100 |
275.0 |
238.0 |
V42L |
6.0 |
150 |
680.0 |
588.0 |
|
View V42 Product Details |
V42 Part Number Matrix PDF |
Cv flow rate in gallons per minute of water at 60ºF, 1 psi pressure drop. |
Kv flow rate in cubic meters per hour of water at 15.5ºC, 1 bar pressure drop. |
Maximum working pressure is 125 psi (8.6 bar). |
Maximum temperature is 140°F (60°C). |
|
|
V46 Series Stainless Steel Valves |
Model |
Pipe Size |
Flow Coefficient |
Inches |
Millimeters |
Cv |
Kv |
V46C |
1.0 |
25 |
14.0 |
12.1 |
V46E |
1.5 |
40 |
33.0 |
28.5 |
V46F |
2.0 |
50 |
54.0 |
47.0 |
|
View V46 Product Details |
V46 Part Number Matrix PDF |
Cv flow rate in gallons per minute of water at 60ºF, 1 psi pressure drop. |
Kv flow rate in cubic meters per hour of water at 15.5ºC, 1 bar pressure drop. |
Maximum working pressure on the threaded valves is 250 psi (17 bar)
and on flanged valves 150 psi (10.3 bar). |
Maximum temperature is 250°F (120°C). |
|
|
Autotrol Flow Meters |
|
Model Number |
Description |
Flow Rate |
Minimum |
Maximum |
Peak |
UA-3023532 |
1 inch Turbine Meter with Stainless Steel NPT Adapters |
0.25 gpm |
35 gpm |
40 gpm |
UA-3023536 |
2 inch Turbine Meter with Stainless Steel NPT Adapters |
2 gpm |
170 gpm |
250 gpm |
|
|
|